Connecting Microsoft Lync 2013 to a SIP Trunk
AudioCodes Mediant E-SBC 72 Document #: LTRT-54004
4.15 Step 15: Configuring Miscellaneous E-SBC
Functionalities
This step shows how to configure the E-SBC's handling of SIP 18x responses received due
to call forking of an INVITE.
In the example scenario, if an 18x with SDP is received, the E-SBC opens a voice stream
according to the received SDP. The E-SBC reopens the stream according to subsequently
received 18x responses with SDP, or plays a ringback tone if a 180 response without SDP
is received. It's mandatory to set this field for the Lync Server 2013 environment.
To configure call forking:
1. Open the General Settings page (Configuration tab > VoIP > SBC > General
Settings).
2. From the 'SBC Forking Handling Mode' drop-down list, select Sequential.
Figure 4-41: Configuring Forking Mode
3. From the ‘SBC Preferences Mode’ drop-down list, select Include Extensions to
ensure that Extension coders and Allowed coders are arranged according to their
order of appearance in the Allowed Coders Group table.
4. Click Submit.