Configuration Note 4. Configuring AudioCodes E-SBC
Microsoft Lync and XO Technology SIP Trunk 41 AudioCodes Mediant E-SBC
3. Configure a Proxy Set for the XO Communications SIP Trunk:
Parameter Value
Proxy Set ID
2
Proxy Address
205.158.163.230:5060
(XO Communications IP address / FQDN and
destination port)
Transport Type
UDP
Enable Proxy Keep Alive
Using Options
Is Proxy Hot Swap
Yes
SRD Index
2 (enables classification by Proxy Set for SRD of IP
Group belonging to XO Communications SIP Trunk)
Figure 4-12: Configuring Proxy Set for XO Communications SIP Trunk
4. Reset the E-SBC with a burn to flash for these settings to take effect (see Section 4.15
on page 70).