6.6.4 Restoring Factory Default Configuration
You can restore the MP-40x to factory default settings using the Web interface, CLI, or
Reset button.
¾ To restore factory default settings using the Web interface:
1. On the main menu bar, click the Load & Save Configuration menu; the ‘Load & Save
Configuration' screen is displayed.
Figure 6-37: Load & Save Configuration Screen
2. Press the “Restore Factory Configuration” button.
¾ To restore factory default settings using the CLI:
To resore to factorz using the CLI use the following command:
erase startup-config
¾ To restore factory default settings using the Reset button:
1. On the front MediaPack's front panel (refer to Table 4-1), press the reset button
uninterruptedly for more than 15 seconds; the gateway is restored to its factory
settings.
2. If required, assign an IP address to the MediaPack.