CTM; Reviewed:
SPOC 11/29/2007
Solution & Interoperability Test Lab Application Notes
©2006 Avaya Inc. All Rights Reserved.
32 of 51
AudioCodesMP118.doc
Step Description
12.
General Advanced Parameters
From the menu shown in Step 11, navigate to Advanced Parameters Æ General
Parameters. Configure the parameters as described below.
Select Enable for the Enable Polarity Reversal and Enable Current
Disconnect fields. This will allow the MP-118 to provide the proper
disconnect indication to various line types.
In the Max Number of Active Calls field, enter a value that is equal to or
greater than the maximum number of ports (FXS + FXO) available on the
gateway. For the compliance test, there were 4 FXS ports and 4 FXO ports.
Default values may be retained for all other fields. Click Submit.