AudioCodes MediaPack 114 Manual do Utilizador Página 280

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 390
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 279
SIP User's Manual 280 Document #: LTRT-65411
MediaPack Series
4.4.10 Analog Telephony Parameters
The analog telephony-related ini file configuration parameters are described in the table
below.
Table 4-10: Analog Telephony ini File Parameters
Parameter Description
Prefix2ExtLine
Defines a string prefix (e.g., '9' dialed for an external line) that
when identified causes the device's FXS port to play a secondary
dial tone and then restart digit collection.
The valid range is a 1-character string. The default is an empty
string.
Note: This parameter is applicable only to FXS interfaces.
PrecedenceRingingType
For a description of this parameter, refer to ''Supplementary
Services'' on page 138.
FXONumberOfRings
Defines the number of rings before the device's FXO interface
answers a call.
When set to 0, the FXO seizes the line after one ring. When set to
1, the FXO seizes the line after two rings.
The valid range is 0 to 255. The default is 0 seconds.
Note: If caller ID is enabled, and if the number of rings defined by
the parameter RingsBeforeCallerID is greater than the number of
rings defined by this parameter, the greater value is used.
CountryCoefficients
Determines the FXO line characteristics (AC and DC) according to
USA or TBR21 standard.
[66] = TBR21
[70] = United States (default)
ChargeCode
This ini file table parameter configures metering tones (and their
time intervals) that the device's FXS interface generates to the Tel
side.
The format of this parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
[\ChargeCode]
Where,
EndTime = Period (1 - 4) end time.
PulseInterval = Period (1 - 4) pulse interval.
PulsesOnAnswer = Period (1 - 4) pulses on answer.
For example:
[ChargeCode]
ChargeCode 1 = 7,30,1,14,20,2,20,15,1,0,60,1;
ChargeCode 2 = 5,60,1,14,20,1,0,60,1;
ChargeCode 3 = 0,60,1;
ChargeCode 0 = 6, 3, 1, 12, 2, 1, 18, 5, 2, 0, 2, 1;
[\ChargeCode]